| INSTALLATION GUIDELINES
CertiVents meet building code section 3205 when six
22" wide vents are installed per 300 sq. ft. of attic floor area
with a ventilated ridge or twelve 22" wide vents when ridge is not
ventilated. Double the above number of vents for 11" wide
CertiVents.
NEW CONSTRUCTION: Place CertiVents on the
underside of the roof sheathing between framing members and slide down
into soffit area 6". Staple CertiVent into place.
Install attic insulation against vents.
EXISTING CONSTRUCTION: Move attic insulation
back from roof sheathing. Place CertiVents on the underside of the
roof sheathing between framing members and slide down into soffit area
6". Staple CertiVent into place. Repack attic
insulation against vents.
When using CertiVents for 16" O.C. framing,
simply snap apart 22" wide vents along score mark for two 11"
vents.
|